Can I Upgrade My Structure Core's Obsolete Firmware?
The short answer is, yes! However, the process will depend entirely on which version of firmware your sensor is now running.
You can download all older firmware updaters and driver packages here:
Because the USB endpoints change from firmware version to firmware version, users will need to update their old firmware in several steps.
Firmware Version | Process | ||
---|---|---|---|
0.9.6 |
|
||
0.9.7, 0.9.8, 0.9.9 |
|
||
1.0, 1.0.1, 1.1 |
|
Note on Skanect Compatibility
Skanect 1.10.2 works with Structure Cores running firmware 0.9.7. If users update to firmware 1.2, they will need to install Skanect 1.11. Downloads can be found here.